Heavy-Duty Materials:
Constructed with galvanized steel or aluminum alloy slats, reinforced with steel guides for impact resistance.
Shopping Mall Fire Door
Characteristics
SUPERIOR FIRE RESISTANCE
NO WATER PROTECTION NEEDED, UNLIKE TRADITIONAL STEEL SHUTTERS, INORGANIC COMPOSITE SHUTTERS ELIMINATE THE NEED FOR WATER SPRAY SYSTEMS, SAVING WATER AND REDUCING INFRASTRUCTURE COSTS. DUAL-TRACK DUAL-CURTAIN, BEST FOR LARGE MALLS, ATRIUMS, INDUSTRIAL ZONES.
SPACE-SAVING DESIGNS
FOLDABLE LIFT-TYPE VARIANTS (E.G., U-SHAPED, CURVED) FIT IRREGULAR OPENINGS WITHOUT SUPPORT COLUMNS, MAXIMIZING ARCHITECTURAL FLEXIBILITY. WATER-MIST STEEL SHUTTER, BEST FOR HIGH-HUMIDITY AREAS (E.G., PARKING GARAGES), RAPID COOLING; SMOKE SUPPRESSION.
LIGHTWEIGHT & STRUCTURAL EFFICIENCY
LOW WEIGHT (7 KG/M²): REDUCES BUILDING LOAD SIGNIFICANTLY, IDEAL FOR LARGE SPANS (E.G., ATRIUMS, SHOPPING MALLS) WHERE STRUCTURAL LOAD CAPACITY IS LIMITED. LOW-GRADE FABRICS MAY MELT BELOW 1100°C, SPECIFY CERAMIC FIBER CLOTH (≥1100°C RATING) AND HIGH-TEMP STITCHING.
Certification Standard
EN16034: the overarching standard for pedestrian and industrial fire/smoke doors & shutters. it mandates assessment against:
EN 1634-1: fire resistance test for doors, shutters, and operable fabric curtains (integrity, insulation)
EN 1364-2: fire resistance tests for non-loadbearing elements - part 2: ceilings (relevant for shutter boxes/cassettes).
EN 1363-1/2: general fire resistance test methods.
EN 13501-2: classification using test data from above
UL 10B / UL 10C: standard fire tests for door assemblies.
UL 263: standard for fire tests of building construction and materials (similar scope to ASTM 119).
Technical data
FIRE RATING | > or =3–4 HOURS (TESTED TO GB9978/EN 1634) | TYPES, APPLICATIONS & BENEFIT | |
BACKFACE TEMPERATURE | AVG. > or =380°C; MAX. SINGLE POINT > or = 180°C | ① DUAL-TRACK DUAL-CURTAIN | |
CURTAIN THICKNESS | 10–20 MM (MULTI-LAYER: CERAMIC FIBER + FIREPROOF CLOTH) | LARGE MALLS, ATRIUMS, INDUSTRIAL ZONES | |
OPERATION SPEED | 2.5–6.4 M/MIN (ELECTRIC); 4–5 M/MIN (GRAVITY FALL) | AIR-LAYER INSULATION; NO WATER SPRAY | |
AIR GAP (DUAL CURTAINS) | 300 MM (OPTIMIZES THERMAL INSULATION) | ② WATER-MIST STEEL SHUTTER | |
SOUND INSULATION | UP TO 42 DB REDUCTION | HIGH-HUMIDITY AREAS (E.G., PARKING GARAGES) | |
MOTOR POWER | 0.25–1.5 KW (AC/DC OPTIONS) | RAPID COOLING; SMOKE SUPPRESSION | |
MAX. DIMENSIONS | WIDTH: < or = 60 FT (18.3 M); HEIGHT: < or = 40 FT (12.2 M) | ③ FOLDABLE LIFT-TYPE | |
STRUCTURAL REQUIREMENTS | IRREGULAR OPENINGS (E.G., ESCALATORS, CURVED WALLS) | ||
WALL STRENGTH | MUST SUPPORT 300–500 KG LOADS; CONCRETE/BRICK WALLS RECOMMENDED. | SPACE-SAVING; COLUMN-FREE DESIGN | |
OPENING TOLERANCE | ≤5 MM DEVIATION (PLUMB/LEVEL) FOR SEAMLESS TRACK ALIGNMENT. | ④ INSULATED STEEL (FIRESTAR) | |
APPLICATION | BUILDING PROJECT, COMPANY, HOME, OFFICE, HOTEL, CHURCH, JUST ANYWHERE YOU WANT! | EXTREME CLIMATES (E.G., COLD STORAGE) | |
PACKAGE | INSIDE: PE PAPER | OUTSIDE: DOUBLE LAYERS CARTON BOX AND WOODEN PALLETS. | MINERAL WOOL CORE; U-VALUE < or = 0.8 W/M²K |
Doors Overviews